Home>Products

Magnetostrictive Displacement Sensor

For reinforced soil and geogrid work, Kingmach Magnetostrictive Displacement Sensor include the JMDL-24XXAT Smart Flexible Displacement Meter. This product is built around patented inductive flux frequency modulation technology and is designed for deformation or strain monitoring in geogrid materials used in reinforced soil and pile-net subgrade foundations. The measuring rod extension is flexible, so it can deform with the geogrid while both ends are clamped by mounting brackets for reliable strain transfer. Listed ranges are 30 mm and 50 mm, with 0.01 mm sensitivity and 0.5%FS accuracy. The non-contact measurement layout keeps the measuring rod and internal coil independent, reducing damage risk during installation and service. A 20-point curve fitting process supports nonlinear correction and accurate displacement output. Kingmach lists a designed service life of up to 30 years for this product, which fits long-term railway, roadbed, slope, and foundation monitoring where buried materials cannot be visually inspected after construction. For this model, the installation record should focus on geogrid layer position, bracket clamping force, fill sequence, compaction stage, cable exit route, and the first stable value after backfilling. Those details are different from crack monitoring because the sensor is working with buried reinforcement deformation rather than an exposed joint. During later review, the curve should be checked with settlement, traffic loading, rainfall, and earthwork records so engineers can understand how the reinforced soil body is behaving.

Application of  Magnetostrictive Displacement Sensor

Application of Magnetostrictive Displacement Sensor

In integrated structural health monitoring, Magnetostrictive Displacement Sensor act as the movement layer inside a wider measurement network. Their role is to show where a point has shifted, how fast the shift is developing, and whether the change agrees with other instruments. Kingmach displacement products can feed digital records into acquisition units and monitoring platforms, while related Kingmach product groups provide strain, load, settlement, tilt, vibration, pore pressure, water level, rainfall, data logging, cables, and software. A practical system may use JMDL-52XXADT meters for precise joint travel, JMDL-31XXAT meters for rock layers, JMDL-24XXAT meters for buried geogrid deformation, and JMLS-22XXADT sensors for longer cable travel. The data chain should define point names, units, zero values, sampling intervals, warning grades, and inspection actions before alarms are enabled. This prevents a displacement curve from becoming an isolated chart. Instead, the reading can be checked beside force, strain, settlement, temperature, rainfall, and construction records, giving engineers a clearer basis for maintenance and warning review. During commissioning, each curve should be verified against the physical point so later reports can be trusted by site teams, designers, and owners. The same record should also note cabinet number, logger channel, cable tag, power supply, and communication route, because many long-term data problems begin outside the sensor body.

The future of Magnetostrictive Displacement Sensor

The future of Magnetostrictive Displacement Sensor

Future Magnetostrictive Displacement Sensor will likely place more intelligence at the edge of the monitoring network. Instead of sending every reading to a platform without review, acquisition units can check whether a displacement jump is physically plausible, whether the temperature moved at the same time, and whether nearby channels changed in the same direction. Kingmach smart products already store measurement time, temperature for temperature versions, absolute displacement, relative displacement, and zero-point values on selected models. That local record can support early filtering and field diagnosis. For remote slopes, dams, subgrades, and tunnel portals, this matters because network access may be unstable and maintenance visits may be expensive. Edge checks can flag cable damage, zero drift, sudden water ingress, or installation movement before the data is accepted as structural deformation. The strongest systems will still depend on careful installation, because digital tools cannot correct a loose bracket, wrong range, or poorly recorded baseline. Clear reporting will make displacement monitoring more useful for non-specialist decision makers while preserving the detail engineers need.

Care & Maintenance of Magnetostrictive Displacement Sensor

Care & Maintenance of Magnetostrictive Displacement Sensor

For automated Magnetostrictive Displacement Sensor, maintenance must include the whole data chain. A sensor can be accurate while the monitoring record is wrong because of channel swaps, wrong units, missed zero values, loose terminals, damaged power supply, or unstable communication. Kingmach displacement products may connect to comprehensive testers, bus modules, automatic acquisition systems, RS485 networks, and monitoring platforms. During commissioning, verify each channel by moving the sensor slightly or checking a known displacement point, then record direction, units, baseline, range, and warning values. During service, check whether data gaps match power failures, communication faults, storms, or cabinet maintenance. Keep spare connectors and labels for field work. When replacing a sensor, do not simply reuse the old zero value; record the replacement time, new model, serial number, range, calibration coefficient, and first stable reading. Keep the installation photo, point number, zero value, and expected movement direction with the commissioning record for later review. If a reading changes after maintenance work, inspect the base, anchor, cable, and cabinet before assuming the structure itself has moved.

Kingmach Magnetostrictive Displacement Sensor

Magnetostrictive Displacement Sensor support safer engineering decisions when the reading is tied to a clear location, a known baseline, and a repeatable acquisition method. Kingmach products list practical field details such as 0.01 mm resolution on several JMDL models, 0.5%FS accuracy on general-purpose, crack, flexible, and formwork models, plus 0.1%FS accuracy on the differential JMDL-52XXADT series. Protection ratings such as IP67 and IP68 help when instruments are exposed to dust, water, concrete work, or outdoor cabinets. RS485 output on digital models allows remote data transfer, while memory functions keep calibration and measurement data close to the sensor. In bridges, buildings, hydropower works, tunnels, railways, slopes, and foundation pits, those details reduce the gap between a specification sheet and actual monitoring work. The better the field record, the faster abnormal movement can be checked. The point should be named on the drawing, linked with its cable route, and checked against the expected movement direction before the first automatic reading is accepted. For daily review, the reading should be compared with nearby points, recent weather, site operations, and any loading event that could explain the movement.

FAQ

  • Q: Which Magnetostrictive Displacement Sensor are used for rock layers or bedrock?
    A: JMDL-31XXAT multipoint meters are used for different surrounding rock layers, while JMDL-32XXAT single-point bedrock meters are used for tunnel rock mass, dam bedrock, slope, or foundation pit movement.

    Q: How many points can the multipoint meter support?
    A: The multipoint installation kit supports three to five monitoring points, with anchor heads fixed at different depths by drilling and grouting.

    Q: What ranges are listed for these models?
    A: Both JMDL-31XXAT and JMDL-32XXAT list 50 mm, 100 mm, and 200 mm models with 0.01 mm resolution.

    Q: Why monitor several depths?
    A: Different layers may move differently. Separating shallow and deep movement helps engineers judge whether the problem is surface creep, deeper rock slip, or overall mass movement.

    Q: What records should be kept?
    A: Keep drilling depth, anchor location, grouting date, channel name, zero value, cable route, and first stable reading.

Reviews

Michael Anderson

The strain gauges and load cells are extremely accurate and stable. They performed very well in our bridge monitoring project. Highly recommended!

Daniel Brown

Excellent environmental monitoring sensors. The data is consistent, and the system integrates smoothly with our existing setup.

Latest Inquiries

To protect the privacy of our buyers, only public service email domains like Gmail, Yahoo, and MSN will be displayed. Additionally, only a limited portion of the inquiry content will be shown.

Isabella***@gmail.comGermany

Hello, we are evaluating weir flow meters for a water management project. Please share accuracy deta...

Sophia***@gmail.comUnited Kingdom

Good day, we need environmental monitoring sensors including temperature, humidity, and wind sensors...

Not finding what you're looking for?
Contact our consultants for more available products.

Request A Quote Now

GET IN TOUCH

If you are interested in our products or want to become our partner.

Please leave your contact information, our team will contact you as soon as possible.

Contact Us Now
Copyright © Kingmach Measurement & Monitoring Technology Co., Ltd.
get a quote
Your Name:
E-mail:*
Company:
Phone/WhatsApp:
Content: