Home>Products

String Potentiometer

The JMDL-52XXADT Differential Displacement Meter is one of the higher precision Kingmach String Potentiometer for structural joints and relative movement. It uses two coupled inductive coils. As the measuring rod moves, magnetic flux changes in the two coils are equal in magnitude and opposite in direction, and the difference is calculated to reduce environmental interference and thermal drift. Listed ranges are 20 mm, 50 mm, and 100 mm. The product provides 0.01 mm resolution, plus or minus 0.1%FS accuracy, RS485 digital output, DC 9V to 24V supply, power consumption below 0.4 W, long-term stability of plus or minus 0.1%FS per year, and an operating temperature range from -40 degrees Celsius to +80 degrees Celsius. Temperature drift is listed as 0.001 mm per degree Celsius. These specifications are useful for bridges, railways, hydropower structures, dams, and buildings where small relative movement needs to be measured across seasons and load changes. During project setup, the measuring point should be matched with the expected travel direction, available mounting space, cable route, and required acquisition interval. This prevents a short-range joint instrument from being used on a long-travel point, or an exposed sensor from being placed where an embedded anchor is needed. It also helps the monitoring team set a baseline that can be defended during acceptance and later maintenance review.

Application of  String Potentiometer

Application of String Potentiometer

In dam and hydropower projects, String Potentiometer can track joint opening, bedrock deformation, gate position, dam body movement, tunnel portal movement, and displacement between monitoring points. The pain point is long service life under water level fluctuation, seepage, temperature change, and difficult access. Kingmach JMDL-32XXAT single-point bedrock meters are designed for dam bedrock deformation and provide 50 mm, 100 mm, and 200 mm ranges with 0.01 mm resolution. JMDL-52XXADT differential meters can monitor relative movement in concrete joints with RS485 digital output and plus or minus 0.1%FS accuracy. JMCW-21XXADT magnetostrictive meters provide 0 to 1000 mm absolute position measurement for gates, equipment stroke, or structural movement. JMLS-22XXADT wire rope sensors support up to 2000 mm for larger displacement paths. Combined with water level, seepage, strain, and temperature monitoring, displacement data helps dam managers understand deformation behavior across operating cycles. During operation, the monitoring team should keep the baseline, temperature, inspection notes, and nearby sensor behavior in the same review file. This makes it easier to tell whether a movement trend comes from normal service, a repair event, changing load, water influence, or developing structural risk. Clear records also help owners decide when a field inspection is needed instead of waiting for visible damage.

The future of String Potentiometer

The future of String Potentiometer

The future of String Potentiometer will include more mixed measurement packages rather than single-sensor orders. A slope package may combine GNSS, multipoint displacement, crack gauges, pore pressure, rainfall, and tilt. A bridge package may combine differential displacement, strain gauges, load cells, accelerometers, temperature, and bearing inspection records. A tunnel package may combine multipoint displacement, convergence, lining strain, water pressure, and vibration. Kingmach already provides a broad product ecosystem across displacement, strain, load, settlement, tilt, environmental monitoring, acquisition equipment, cables, and software. The next step is project-specific packaging where the displacement instrument is selected together with its data logger, cable, cabinet, communication route, warning logic, and maintenance plan. That approach reduces mismatched hardware and makes the monitoring system easier to operate after handover. It also helps procurement teams compare complete monitoring functions instead of comparing sensor names alone. For complex infrastructure, the package should define which movement point answers which engineering question before hardware is ordered.

Care & Maintenance of String Potentiometer

Care & Maintenance of String Potentiometer

For draw-wire String Potentiometer, the cable path is the part that most often decides data quality. Kingmach JMLS-22XXADT wire rope sensors use a plastic-coated stainless steel cable, spool, precision rotary sensor, RS485 communication, IP67 sealing, and ranges up to 2000 mm. During installation, align the cable with the expected movement direction, keep the pull smooth, and avoid rubbing against concrete edges, steel corners, temporary supports, or moving machinery. Do not overextend the cable beyond its range, and do not let it snap back during inspection. Check the anchor point, cable coating, spool movement, connector sealing, and lightning protection after storms or heavy site work. For long-term dam, tunnel, slope, or machinery monitoring, include cable tension and cable path photos in routine maintenance records. A clean cable route gives more reliable displacement data than any later software correction. Keep the installation photo, point number, zero value, and expected movement direction with the commissioning record for later review. If a reading changes after maintenance work, inspect the base, anchor, cable, and cabinet before assuming the structure itself has moved.

Kingmach String Potentiometer

Long-term projects need String Potentiometer that can survive the same weather, vibration, cable pulling, and site handling as the structure itself. Kingmach designs several smart displacement products with built-in memory chips, digital detection, strong anti-interference capability, and direct display through compatible testers. The JMDL-22XXAT crack gauge stores up to 600 measurement results and covers 20 mm, 50 mm, 100 mm, and 200 mm models. The JMDL-21XXAT general-purpose model stores up to 800 records and can save time, temperature, absolute displacement, relative displacement, and zero-point values. These records matter during handover because the original baseline, later shifts, and abnormal readings can be checked without relying only on handwritten notes. For bridges, dams, tunnels, slopes, and buildings, that traceability helps maintenance teams judge whether a movement event is isolated, repeated, or linked with surrounding construction and environmental change. The point should be named on the drawing, linked with its cable route, and checked against the expected movement direction before the first automatic reading is accepted. For daily review, the reading should be compared with nearby points, recent weather, site operations, and any loading event that could explain the movement.

FAQ

  • Q: How should String Potentiometer be maintained?
    A: Inspect brackets, anchors, measuring rods, cable routes, connectors, waterproof seals, cabinet wiring, grounding, and channel labels at planned intervals.

    Q: What signs suggest a data problem rather than real movement?
    A: Flat lines, sudden jumps after cabinet work, repeated communication gaps, impossible readings, or disagreement with nearby points may indicate sensor, cable, power, or channel issues.

    Q: Can temperature affect displacement data?
    A: Yes. Some products include low temperature sensitivity, differential measurement, or temperature records, but temperature should still be reviewed with the movement trend.

    Q: Should zero values be reset often?
    A: No. Resetting without a field reason can hide structural movement. Record the event, reason, and new baseline if a reset is required.

    Q: What makes a displacement record useful during handover?
    A: A useful record includes model, range, serial number, calibration coefficient, baseline, installation photo, point location, latest trend, warning level, and maintenance notes.

Reviews

Matthew Garcia

Instrumentation cables are durable and perform well even in harsh environments. Will definitely order again.

Robert Taylor

The weir flow meter is well-built and delivers accurate measurements. Great value for water management applications.

Latest Inquiries

To protect the privacy of our buyers, only public service email domains like Gmail, Yahoo, and MSN will be displayed. Additionally, only a limited portion of the inquiry content will be shown.

Mia***@gmail.comNetherlands

Dear team, we are interested in your readouts & data loggers compatible with multiple sensors. Do yo...

Isabella***@gmail.comGermany

Hello, we are evaluating weir flow meters for a water management project. Please share accuracy deta...

Not finding what you're looking for?
Contact our consultants for more available products.

Request A Quote Now

GET IN TOUCH

If you are interested in our products or want to become our partner.

Please leave your contact information, our team will contact you as soon as possible.

Contact Us Now
Copyright © Kingmach Measurement & Monitoring Technology Co., Ltd.
get a quote
Your Name:
E-mail:*
Company:
Phone/WhatsApp:
Content: